Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FB250
CROSS SECTION (Cu):2,50 mm²
STRANDED COPPER CONDUCTER
(Cu):50x0,24 mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 2,85
MIN. WALL THICKNESS
(mm):0,28
APPROXIMATE WEIGHT
(kg/km):26,00
CONDUCTOR RESISTANCE:<7,6 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
Battery Cycle Count
A typical cell phone battery goes through approximately 500 cycles before retaining at least 80% of its original capacity. Made from new materials, our batteries have zero cycles, ensuring the maximum number of cycles you can use.
Zero Cycle Count, so you have the maximum amount of cycles remaining.
Lithium-Ion Polymer
technological materials
Strict QC test
Less than 1% failure rate
12 Months Warranty
Specifications
Aluminium extruded body with electrostatic powder coated
Electrostatic powder coated aluminium die cast end caps
Mid Power LED light source
LED (L80/B10) + DRIVER life time more than 50.000 Hours
Tempered (clear and frosted) glass cover with IK10 grade
High efficient PMMA, Opal, semi-transparent or transparent diffuser option
Input Voltage: 198-264V AC, 176-280V DC, 50-60 Hz
Operating Temperature (Ta): -400C / +700C
Applications
Zone 2 - Zone 22 applications
Industrial Facilities
Oil Rafineries
Gas Stations
Petrochemical Facilities
These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FLY075
CROSS SECTION (Cu):0,75 mm²
STRANDED COPPER CONDUCTER
(Cu):24x0,19 mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05):PVC (according to ISO 6722-1, CLASS B AND CLASS C) 2,4
WALL THICKNESS min
(mm):0,60
APPROXIMATE WEIGHT
(kg/km):12,00
CONDUCTOR RESISTANCE:<24,7 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FB100
CROSS SECTION (Cu):1,00 mm²
STRANDED COPPER CONDUCTER
(Cu):32x0,19 mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 2,00
MIN. WALL THICKNESS
(mm):0,24
APPROXIMATE WEIGHT
(kg/km):11,00
CONDUCTOR RESISTANCE:<18,1 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)
Areas of Usage: These multiple wire bare copper or tinned copper cables, produced with flame retardant durable PVC are used in the installation of motor vehicles.
PRODUCT CODE:FB1600
CROSS SECTION (Cu):16,00 mm²
STRANDED COPPER CONDUCTER
(Cu):126x0,39mm
INSULATION MATERIAL AND DIAMETER(mm ±0,05) :PVC (according to ISO 6722-1, CLASS B AND CLASS C) 6,80
MIN. WALL THICKNESS
(mm):0,52
APPROXIMATE WEIGHT
(kg/km):170,00
CONDUCTOR RESISTANCE:<1,16 Ω/km
WORKING TEMPERATURE:-40 to +105°C (CLASS B)